electrical center b2c
TX6-D Series 72×72mm PID Temperature Controller universal thermocouple & RTD input · relay / SSR / 0-10 V / 4-20 mA output
Couldn't load pickup availability
72x72mm PID Temperature Controller ,72 x 72mm (1/4 DIN class) ,68x68mm cutout temperature controller
shimaden sr92 replacement 72x72,
sr92 alternative shallower depth pid,
omron e5ec 72x72 replacement,
e5ec rx4abm alternative temperature controller,
autonics tk4m alternative 72x72,
delta dtk7272r01 alternative dual output,
fotek mt72 replacement pid controller,
72x72 dial thermostat upgrade to pid
The TX6-D is a panel-mounted PID temperature controller in a 72 × 72 mm case with a 68 × 68 mm cutout. DIN 43700 has no such size. It grew up in the Japanese, Korean and Chinese instrument market as the answer to a real gap: a 48 × 48 mm controller gives you four small digits and a cramped keypad; a 96 × 96 mm controller eats a cabinet door for a single loop. At 72 × 72 the characters are legible from the aisle and four to eight zones still fit across one panel face. In North America the format is uncommon, which means two things — buyers rarely find it in stock, and almost nobody writes about it. This document does both.
TX6D Product DATA SHEET
Available Configurations
All ten share the same 72 × 72 mm case, the same 68 × 68 mm cutout, the same universal input and the same 75 mm depth. They differ only in what they drive and whether they can talk.
| Part number | Input | Output 1 | Output 2 | Comms | Alarm | Typical use |
|---|---|---|---|---|---|---|
| TX6-DK1220 | TC / RTD universal | Relay 3 A | — | — | AL1 | General-purpose drop-in for the 72×72 controller in your panel; direct contactor or pilot-duty switching |
| TX6-DK1224 | TC / RTD universal | Relay 3 A | Relay 3 A | — | AL1 + AL2 | Two-stage heat/cool, or one control stage plus a fully independent high-limit alarm |
| TX6-DK120T | TC / RTD universal | Relay 3 A | — | RS-485 Modbus | AL1 | Stand-alone machine reporting SV, PV and alarm state to the plant PLC or HMI |
| TX6-DK1620 | TC / RTD universal | SSR drive 12 V | — | — | AL1 | SSR + heatsink firing, zero-cross switching, silent and long-life |
| TX6-DK220T | TC / RTD universal | SSR drive 12 V | — | RS-485 Modbus | AL1 | Multi-zone networked ovens and extrusion barrels under PLC supervision |
| TX6-DK420 | TC / RTD universal | 0-10 V DC | — | — | AL1 | Analog setpoint input or SCR firing-board drive on an existing 0-10 V plant |
| TX6-DK1520 | TC / RTD universal | Relay 3 A | 0-10 V DC | — | AL1 | Relay for the contactor stage with analog retransmission to a recorder or second controller |
| TX6-DK320 | TC / RTD universal | 4-20 mA | — | — | AL1 | Long-run analog retransmission to a PLC analog input or chart recorder |
| TX6-DK320T | TC / RTD universal | 4-20 mA | — | RS-485 Modbus | AL1 | Full traceability — analog loop plus Modbus supervisory on one part number |
| TX6-DA320 | 4-20 mA (process) | 4-20 mA | — | — | AL1 | Pressure, flow or level loop indicated and controlled in engineering units |
TX6-DK1224 (relay + relay) gives you a real second stage or a fully independent high-limit alarm. TX6-DK1520 (relay + 0-10 V) gives you a contactor stage with analog retransmission. Every other code is single-output — if your circuit needs two, do not try to parallel the terminals.-LV to the part code and state it explicitly on the PO — a 24 V unit ordered without the suffix arrives as 120/240 V.General Specifications
| Item | Specification |
|---|---|
| Product family | YHKJ TX6-D — intelligent PID temperature / process controller |
| Panel format | 72×72mm, 72 × 72 mm (2.83 × 2.83 in) face; 68 × 68 mm (2.677 × 2.677 in) cutout — NOT a DIN 43700 standard size |
| DIN cross-reference | Smaller than 1/4 DIN (92×92 cutout); larger than 1/8 DIN (92×45) and 1/16 DIN (45×45). Not interchangeable with any of them without re-cutting the panel |
| Overall depth | 75 mm (2.95 in) behind panel, on the 68 × 68 × 75 mm housing; add 40-50 mm (1.6-2.0 in) for terminal and wire-bend clearance, giving roughly 120 mm (4.7 in) net |
| Panel thickness | 1.0 - 4.0 mm (0.04 - 0.16 in) — TBC against the factory drawing |
| Mounting | Panel mount with supplied clamping bracket and gasket; screw-terminal rear barrier strip |
| Display | Triple-line LED — PV (white/red, upper), SV (green, middle), MV output % (orange, lower); 8-segment output bar across the lower bezel |
| Status indicators | OC (output), AL1, AL2, plus six output-mode lamps (OUT / AT / MAN / COM / heating / cooling) — 8 lamps total as supplied |
| Operator keys | MODE, ◀◀ (shift), ▼ (decrease), ▲ (increase); 4-digit password lock on the engineering menu |
| Control modes | PID with auto-tune, or ON/OFF with adjustable differential; heating (reverse) or cooling (direct) action |
| Control period | Selectable cycle time; 0.5-2.0 s typical for SSR drive, 20-30 s typical for relay |
| Alarms | 1 or 2 outputs (AL1 / AL2), 17 alarm modes: deviation high/low, band, absolute high/low, heater-break, sensor-break, timer-end |
| Timer | Built-in 0-9999 min or s, 5 timing modes, timer-end alarm via CYPT programming |
| Soft start | Ramp-to-setpoint on power-up or setpoint change; limits thermal shock on elements and refractories |
| Digital filter | FIL 0-100 — moving-average input damping for electrically noisy panels |
| Supply voltage | 100-240 VAC, 50/60 Hz (standard); 24 VAC / 24 VDC ±10 % (suffix -LV) |
| Power consumption | TBC — factory nameplate pending. Budget ≤ 6 VA (≈ 4 W) for panel heat-load calculation |
| Ambient rating | 0 to 50 °C (32 to 122 °F); 30-85 % RH non-condensing; storage -20 to 65 °C (-4 to 149 °F) |
| Front-panel rating | TBC — IP54 as supplied / IP65 with gasket / IP66 optional. Confirm the rating before specifying a washdown or outdoor location |
| Rear terminals | IP20 — must be mounted inside an enclosure, behind a NEMA 1 or better door |
| Minimum mounting pitch | TBC — 72×72 bodies side-by-side: confirm the minimum horizontal and vertical centre-to-centre spacing with the factory drawing before laying out a multi-zone door |
| Weight | Approx. 300 g (0.66 lb) — TBC |
| Warranty | 24 months from date of shipment |
Care Instructions
Care Instructions