West 6100 Alternative | TX6A 1/16 DIN, 76mm Depth PID Temperature Controller
Couldn't load pickup availability
Same 45×45 mm Cutout, 76 mm Less Panel Depth
24VDC temperature controller 1/16 din
45x45mm cutout temperature controller
Intro block
The West 6100+ (P6100) is a well-regarded 1/16 DIN controller — and a physically demanding one, needing roughly 110 mm of clear depth behind the panel. In a shallow or cable-crowded cabinet that single dimension decides the job: the original will not go back in, and neither will anything else in the same deep-body class. West's own guidance for these installations points to the CAL MAXVU16 at around 76 mm. The TX6A occupies the same 45×45 mm cutout in the same shallow class, with universal thermocouple/RTD input, four output families and optional RS-485 Modbus.
TX6A DATA SHEET
Depth is the whole story
| Controller | Cutout | Panel depth | retrofit verdict |
|---|---|---|---|
| West 6100+ (P6100) | 45 × 45 mm | ~110 mm | Fails in shallow cabinets |
| Shimaden SR1 | 45 × 45 mm | 111 mm (body 100 mm) | Same deep-body problem |
| CAL MAXVU16 | 45 × 45 mm | 67 mm (catalog 70 mm) | Shallow-class reference |
| Omron E5CC | 45 × 45 mm | 60 mm / 73.1 mm with cover | Shallow |
| Autonics TC4S / TCN4S | 45 × 45 mm | 64.5 mm | Shallow |
| YHKJ TX6A | 45 × 45 mm | 76 mm | Shallow class, subject to drawing |
Full cross-reference
| Parameter | West 6100+ / West 8100 | CAL MAXVU16 / 9500P | YHKJ TX6A |
|---|---|---|---|
| Frame / cutout | 48×48 / 45×45 mm (8100: 48×96 / 45×92) |
48×48 / 45×45 mm | 48×48 / 45×45 mm (TX6B: 48×96 / 45×92) |
| Depth | ~110 mm | 67–70 mm | 76mm |
| Input | Universal TC/RTD + mV/V/mA | TC/RTD, universal on 9500P | K/J/T/R/S/B/E/N, Pt100/Cu50; 4–20 mA on AA320 |
| Accuracy | 6100+: ±0.25% FS | ±0.25% FS (MAXVU) | ±0.25% FS |
| Sample rate | 10 readings/sec (6100+) | 10/s | 10/s |
| Output | Relay / logic (SSR) / TRIAC / 4–20 mA | Relay / SSR / analogue | Relay / SSR 12 V / 0–10 V / 4–20 mA |
| Alarms | Configurable AL1/AL2, 17 modes | AL1 + AL2 | AL1, or AL1+AL2 (suffix 4) |
| Comms | RS-485 Modbus option | RS-485 Modbus option | RS-485 Modbus RTU, addr 1–247 (“T”) |
| Supply | 100–240 VAC, 24 VAC/VDC option | 100–240 VAC / 24 V AC-DC | 100–240 VAC std; -LV for 24 V |
| Approvals | CE, cUL, UL, CSA, ROHS, WEEE | CE, cUL, UL, CSA, ROHS, REACH | UL 60730-1/-2-9 design basis; UL Recognized; UL Listed TBC |
| IP rating | IP65 / NEMA 4X front (6100+) | IP65 front (MAXVU panel) | IP65 — confirm front rating |
Choose the TX6A part number
| If the outgoing unit is… | Order | Configuration |
|---|---|---|
| West 6100+ relay output | TX6-AK1220 / AK1224 | Relay; 1224 adds second alarm |
| West 6100+ relay + comms | TX6-AK120T | Relay + RS-485 Modbus |
| West 6100+ logic/SSR output | TX6-AK1620 / AK220T | 12 V SSR drive; 220T adds RS-485 |
| West 6100+ 4–20 mA output | TX6-AK320 / AK320T | 4–20 mA; “T” adds RS-485 |
| West 8100 (48×96, 45×92) | TX6B series | 1/8 DIN — see the TX6B datasheet |
| Shimaden SR1 (deep body) | Same mapping as West 6100+ | Match output family; depth check mandatory |
Retrofit sequence for shallow cabinets
H2 — FAQ
My cabinet only has 75 mm behind the panel. Will this fit?
That is exactly the case this page is for. The West 6100+ needs about 110 mm, so it will not go back in; the TX6A is in the shallow 60–70 mm class alongside the CAL MAXVU16 and Omron E5CC. Confirm the published depth on the TX6A outline drawing against your measured 75 mm — and allow a few millimetres for the terminal cover and wire bend radius, which is what usually costs you the last clearance.
Does the TX6A really save 43 mm?
110 mm minus the TX6A's confirmed depth. That headline figure is only valid once the factory drawing is published — treat it as provisional until then, and re-state the saving from the measured value. Even a 30 mm gain is usually enough to clear a DIN rail or a door frame.
What if I need an IP65 / NEMA 4X front?
The West 6100+ carries an IP65/NEMA 4X front. Check the TX6A's published front-of-panel rating before specifying a washdown or dusty environment. If the TX6A's rating is lower, the honest answer is to fit it behind a sealed panel-mount gasket assembly or retain the original in that location — do not substitute on a food or pharma washdown line without confirmation.
Can the TX6A replace a West 8100 as well?
Not directly. The 8100 is a 48×96 mm 1/8 DIN unit on a 45×92 mm cutout. Use the TX6B series for that aperture. Same part-number logic, different frame — and the TX6B is a separate datasheet.
Will my Modbus network survive the swap?
Physically yes — RS-485 Modbus RTU, address 1–247, 1.2–115.2 kbps on the “T” suffixed models. Logically you must re-point the register map, which is not shared with West. Budget the HMI tag change into the changeover, and keep a printed copy of the old tag list.
Is this a West or CAL product?
No. The TX6A is an independent product of YHKJ, distributed by Electrical Center B2C. West® and CAL Controls® are trademarks of their respective owners; those names appear here only to identify equipment the TX6A is mechanically compatible with.