electrical center b2c
YHKJ TX6B 1/8 DIN PID Temperature Controller 48x96 | YHKJ Universal Input · Dual Display · Relay/SSR/0-10V/4-20mA · RS-485
Couldn't load pickup availability
pid temperature regulator 1/8 din, thermal process controller 4896, digital industrial thermostat 48x96, dual loop temperature controller, 1/8 din process controller ,panel meter with pid output, temperature controller with dual sv, dual output pid controller 48x96
The TX6B is a panel-mounted PID temperature controller in the industry-standard 1/8 DIN footprint. It accepts every common North American sensor — type J and K thermocouples, 100 Ω platinum RTD and 4-20 mA process signals — drives relay, SSR, 0-10 V or 4-20 mA outputs, and speaks Modbus over RS-485. Where the 48×48 TX6A is the answer for a tight panel, the TX6B is the answer where the operator needs to read the loop from across the aisle, or where the job needs a real second output for two-stage control or analog retransmission.
TX6B DATA SHEET
General Specifications
| Parameter | Specification |
|---|---|
| Product family | YHKJ TX6B — intelligent PID temperature / process controller |
| Panel format | 1/8 DIN, 48 × 96 mm (1.89 × 3.78 in) face; 45 × 92 mm (1.772 × 3.622 in) cutout |
| Overall depth | 75 mm (2.95 in) behind panel, on the 45 × 92 × 75 mm housing; add 40-50 mm (1.6-2.0 in) for terminal and wire-bend clearance |
| Mounting | Panel mount with supplied clamping bracket and gasket; screw-terminal rear barrier strip |
| Display | Dual 4-digit 7-segment LED — PV (white/red), SV (green); 10-segment MV output bar (10-100 %) |
| Status indicators | °F / °C, AT, PRO, COM, MAN, OUT1, OUT2, STOP, AL1, AL2, heating / constant / cooling arrows |
| Operator keys | MODE, ◀◀ (shift), ▼ (decrease), ▲ (increase); 4-digit password lock on the engineering menu |
| Control modes | PID with auto-tune, or ON/OFF with adjustable differential; heating (reverse) or cooling (direct) action |
| Control period | Selectable cycle time; 0.5-2.0 s typical for SSR drive, 20-30 s typical for relay |
| Alarms | 1 or 2 outputs (AL1 / AL2), 17 alarm modes: deviation high/low, band, absolute high/low, heater-break, sensor-break, timer-end |
| Timer | Built-in 0-9999 min or s, 5 timing modes, timer-end alarm via CYPT programming |
| Soft start | Ramp-to-setpoint on power-up or setpoint change; limits thermal shock on elements and refractories |
| Digital filter | FIL 0-100 — moving-average input damping for electrically noisy panels |
| Supply voltage | 100-240 VAC, 50/60 Hz (standard); 24 VAC / 24 VDC ±10 % (suffix -LV) |
| Power consumption | ≤ 6 VA (≈ 4 W) |
| Ambient rating | 0 to 50 °C (32 to 122 °F); 30-85 % RH non-condensing; storage -20 to 65 °C (-4 to 149 °F) |
| Front-panel rating | NEMA 4X / IP65 (IP66 optional) when mounted with the supplied gasket |
| Rear terminals | IP20 — must be mounted inside an enclosure |
| Weight | Approx. 320 g (0.71 lb) |
| Warranty | 24 months from date of shipment |
Input & Output Specifications
Sensor input
| Item | Specification |
|---|---|
| Thermocouple | J, K, T, E, R, S, B, N — see range table, °F and °C |
| RTD | 3-wire 100 Ω Pt, DIN 0.00385 (α = 0.00385); -328 to 1112 °F (-200 to 600 °C) |
| Process current | 4-20 mA (TX6-BA320 process-input model), 250 Ω shunt internally terminated |
| Accuracy | ±0.5 % of full scale ±1 digit (TC / RTD); ±0.2 % FS ±1 digit on analog input |
| Cold-junction compensation | Automatic, built-in |
| Sensor-break action | Control output driven off; Err and AL1 asserted |
| Scan rate | 100 ms typical |
| Decimal / scaling | Selectable decimal position; analog input scalable -1999 to 9999 counts |
Control output & comms
| Item | Specification |
|---|---|
| Relay (code 1) | SPST-NO, 3 A @ 250 VAC resistive (1.5 A inductive); pilot duty 250 VA; mechanical life 10⁷ ops |
| SSR drive (code 2) | 12 V DC pulse, ≈ 20 mA max — drives any standard panel SSR with DC input |
| Voltage analog (code 4) | 0-10 V DC, max load ≥ 500 Ω, 12-bit resolution |
| Current analog (code 3) | 4-20 mA, max loop burden 500 Ω, 12-bit resolution |
| Auxiliary / alarm relay | SPST-NO, 3 A @ 250 VAC resistive (where fitted) |
| Isolation | Input / output / supply galvanically isolated; outputs isolated from logic |
| RS-485 (suffix T) | Modbus RTU, address 1-100, 2400 / 4800 / 9600 / 19.2k / 38.4k baud, 2-wire half-duplex |
Thermocouple & RTD ranges — °F / °C
| Sensor type | Range (°F) | Range (°C) |
|---|---|---|
| Type J | -148 to 2192 °F | -100 to 1200 °C |
| Type K | -328 to 2372 °F | -200 to 1300 °C |
| Type T | -328 to 752 °F | -200 to 400 °C |
| Type E | -328 to 1112 °F | -200 to 600 °C |
| Type N | -328 to 2372 °F | -200 to 1300 °C |
| Type R | 32 to 3092 °F | 0 to 1700 °C |
| Type S | 32 to 3092 °F | 0 to 1700 °C |
| Type B | 212 to 3272 °F | 100 to 1800 °C |
| 100 Ω Pt RTD (3-wire) | -328 to 1112 °F | -200 to 600 °C |